What the two periods measured
The 2023 conventional-milling average covered about 276,100 tonnes of feed: 38.86 kWh/t. In February 2025, staged milling used 196,229.6 kWh for 7,345.48 tonnes of feed, including slip pumping, or 26.71 kWh/t. The recorded difference was 12.15 kWh per tonne of feed. The periods differed in length and the recorded discharge fineness also differed. A new line needs trials on its own feed to estimate achievable savings.
Price load shifting separately
The plant report modelled moving approximately 29,000 kWh a month out of a higher-price period. With a tariff difference of CNY 0.60/kWh, the estimated tariff saving alone was CNY 17,400 a month. To evaluate another plant, multiply metered energy in each time band by the applicable tariff under each schedule and compare total bills. This avoids counting shifted energy twice.
Include labour and grinding media
The historical operation added about CNY 10,000 per month in labour for opening hatches and discharging slip. For a new project, compare electricity, media wear, labour and maintenance per tonne of accepted dry solids at equivalent quality and delivery, then apply comparable annual output. Account separately for capital outlay, downtime and payback. Under a media-wear service agreement, the plant can retain the electricity savings while GONGKEE takes responsibility for media wear on agreed terms after trial acceptance.