Size the drive for a loaded start
The original side-mounted motor turned the mixer shaft through pulleys and a belt. A disc-type permanent-magnet outer-rotor motor drives the shaft directly and removes belt tensioning and replacement from the maintenance schedule. Specify the actual impeller speed, batch load and starting duty. Motor nameplate speed alone does not give impeller speed.
Read the two meter periods in context
Both motors in one ceramic plant were rated at 7.5 kW. The earlier record shows 1,395 kWh over 264 hours and the later record shows 454 kWh over 144 hours. The averages were 5.28 and 3.15 kW over elapsed calendar time. Actual running hours and accepted slurry output in each period still need to be matched.
Compare energy per tonne of accepted slurry
Run the same recipe at a comparable batch load and mixing target. Record shaft speed, run time and electrical energy at the drive input. Sample the slurry against the plant’s existing quality criteria, then divide batch kWh by accepted tonnes. This gives the plant a basis for the next retrofit decision.